Lojer MANUTHERA 242 - User Manual

Lojer MANUTHERA 242
2 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Ver. 1.0, 25/10/2022
•Theseinstructionsdonotreplacetheactualinstructionsforuse.Readtheinstructionsforusebefore
usingthedevice.
•Beforestartingcleaning,makesurethatthepowercordisdisconnectedandthatthedevice’sfunctionshave
beenlocked.Checkbytestingthefunctions.
•Devicesequippedwithabatterysystemcanbeadjustedevenwhenthepowercordisunpluggedorduringa
poweroutageaslongthereispowerinthebatteries.Theoperationsofthedevicemaybepreventedbyusing
thelockingfeature.
•Donotmachinewashorusewatersprayforcleaning.Donotcleaninhightemperatureorairhumidity
byusinge.g.steamorhotwater.
•Allsurfacesmustbeallowedtodryaftercleaningordisinfectingbeforeusingthedeviceoritsaccessories.
WARNING
•Cleantheproductasinstructedbeforeuse.
•Donotuseanyunsuitablecleanersordisinfectantsforcleaninganddisinfectingthedevice.
Seetheinstructionsbelow.Followtherespectivemanufacturer’sinstructions.
•Allowthesurfaceofelectriccomponentstocooloffbeforecarryingoutmaintenanceorcleaningprocedures.
•Avoidmoistureenteringtheconnectionpoints.Excessivemoisturecancauseliquidpoolinganddamage
thedevice.
CAUTION
Cleaning
Cleanthedeviceasepticallyfollowingtheworkorder:Fromtoptobottomandfromcleanesttodirtiest.
Takeintoaccountthefollowingthingswhencleaningthedevice:
• Thedevicecannotbemachinewashed.
• Cleanstainsandvisibledirtassoonaspossible.
> Allsecretionstainsshould
beremovedimmediatelyaftertheyappear.
>
Somesubstancesusedincareworkmaycausepermanentstains.
• Makesurethatthepowercordisdisconnectedandthatthedevice’sfunctions
havebeenlocked.
• Thesurfacesshouldalwaysbecleanedbeforedisinfection.
>
Followthecleaninginstructionsgivenbythedetergentmanufacturers.
• Inordertokeepthesurfacesingoodcondition,cleanthedeviceregularly.
>
Alwayscleanthedevicebetweenpatients.
• Anysurfaceshouldnotbesubjecttolong-termexposurebyanytypeofliquids.
CONFIDENTIAL |LojerOy|Putajantie42,FI38210Sastamala,Finland|www.lojer.com
LOJER MANUTHERA 242
Cleaning instructions
Question and Answer IconNeed help?

Do you have a question about the Lojer MANUTHERA 242 and is the answer not in the manual?

Overview

The Lojer Manuthera 242 is a medical device designed for patient care, with a strong emphasis on ease of cleaning and maintenance. This document outlines the cleaning and disinfection procedures to ensure the device remains in optimal condition and to prevent the transmission of harmful microbes.

Function Description

The Lojer Manuthera 242 is a versatile device, likely a treatment table or similar patient support system, given the context of cleaning instructions for surfaces and the mention of adjustable features. It is designed to facilitate various medical procedures and patient positioning. The device can be equipped with a battery system, allowing for adjustments even during power outages or when unplugged, provided there is sufficient battery power. A locking feature is incorporated to prevent unintended operations, enhancing safety during use and maintenance.

Important Technical Specifications

While specific technical specifications like dimensions, weight capacity, or power consumption are not detailed in the provided text, several operational and maintenance-related specifications can be inferred:

  • Power Source: The device operates with a power cord, and some models are equipped with a battery system for cordless operation or backup power.
  • Adjustability: The device features adjustable components, which can be operated even on battery power.
  • Locking Mechanism: A locking feature is present to prevent device functions, crucial for safety during cleaning and maintenance.
  • Material Compatibility: The device's surfaces are compatible with specific cleaning agents (neutral pH 6-8 or weakly alkaline pH 8-10 detergents) and disinfectants (e.g., max. 70% ethanol or 60% propanol, and a list of tested commercial disinfectants). It is explicitly stated that solvents, abrasive cleaning agents, or scouring pads should not be used as they can damage the surfaces.
  • Cleaning Limitations: The device cannot be machine washed or cleaned with water spray, steam, or hot water.

Usage Features

The Lojer Manuthera 242 is designed with user convenience and patient safety in mind, incorporating features that facilitate its use in a medical setting:

  • Battery System: For models equipped with a battery system, the device can be adjusted independently of a power outlet, offering flexibility and uninterrupted operation during power disruptions.
  • Locking Feature: The ability to lock the device's functions is a critical safety feature, preventing accidental movements or adjustments, especially important during patient transfers or maintenance.
  • Ergonomic Design (Inferred): The emphasis on cleaning various surfaces, including "moulded soft surfaces" and "difficult stains, corners and other hard to reach places," suggests a design that considers both patient comfort and the practicalities of maintaining hygiene in a medical environment.
  • Ease of Disinfection: The device's materials are compatible with a range of tested disinfectants, simplifying the process of maintaining a sterile environment.

Maintenance Features

Maintenance of the Lojer Manuthera 242 is primarily focused on thorough cleaning and disinfection to ensure longevity and hygiene. The manual provides detailed instructions for these processes:

  • Pre-Cleaning Preparations: Before any cleaning, the power cord must be disconnected, and the device's functions locked. For battery-equipped devices, adjustments can still be made if there's power, but locking is essential for safety during cleaning.
  • Aseptic Cleaning Procedure: Cleaning should follow an aseptic work order: from top to bottom and from cleanest to dirtiest.
  • Immediate Stain Removal: Stains and visible dirt, especially secretion stains, should be removed as soon as possible to prevent permanent marks.
  • Surface Cleaning:
    • Frame and Hard Surfaces: Clean with a damp microfiber cloth and a mild detergent solution (neutral pH 6-8 or weakly alkaline pH 8-10). Special attention should be given to contact surfaces.
    • Moulded Soft Surfaces: Clean with a damp microfiber cloth and a neutral detergent solution (pH 6-8).
    • Difficult Stains: A soft brush can be used for difficult stains, corners, and hard-to-reach areas on hard surfaces.
  • Detergent Residue Removal: After cleaning, surfaces should be wiped with a cloth dampened with clean water to remove detergent residues.
  • Drying: All surfaces must be allowed to dry completely after cleaning or disinfecting before the device is used or stored. This is crucial to prevent moisture from entering connection points, which could lead to liquid pooling and device damage.
  • Regular Cleaning: The device should be cleaned regularly, and always between patients, to maintain good surface condition.
  • Disinfection Protocol:
    • Disinfection should only be performed after cleaning and when justified (e.g., to prevent microbe transmission).
    • Use disinfectants suitable for medical devices, applied with a damp microfiber cloth, following the manufacturer's instructions.
    • Examples of suitable disinfectants include max. 70% ethanol or 60% propanol for secretion stains.
    • A list of suitable tested disinfectants is provided, including various alcohols, biguanides, aldehydes, oxidizing agents, phenols, and active chlor compounds.
    • Surfaces should be wiped with a clean water-dampened cloth after disinfection and allowed to dry completely.
  • Moisture Control: Avoid moisture entering connection points, as excessive moisture can cause damage. Surfaces should not be subjected to long-term exposure to any type of liquids.
  • Temperature Considerations: Electric components should be allowed to cool off before maintenance or cleaning procedures. Cleaning should not be done in high temperature or air humidity environments using steam or hot water.
  • Prohibited Cleaning Agents: Solvents, abrasive cleaning agents, or scouring pads must not be used as they can damage the surfaces. Unsuitable cleaners or disinfectants should be avoided.

Lojer MANUTHERA 242 Specifications

General IconGeneral
BrandLojer
ModelMANUTHERA 242
CategoryMedical Equipment
LanguageEnglish