Description:
The batch length is specified in hours, or optionally in the number of packs if a PEC is fitted. The
batch length represents the amount of production statistics that will be accumulated, before they are
transmitted down the serial link to a printer or computer, and then reset to zero.
Press the [ENTER] key, and then the [] and [] keys to adjust the batch length as necessary.
Scope:
00.00 to 24.00 for timed batch interval
0 to 9999 for pack batch interval
Default:
01.00 for time.
Notes:
Batch reports must be enabled in the Report Options menu for this menu entry to appear.
*BTCH LENTH 1.00
BATCH LENGTH

Other manuals for Loma Superscan Micro ISC

Question and Answer IconNeed help?

Do you have a question about the Loma Superscan Micro ISC and is the answer not in the manual?

Summary

Loma Superscan Micro ISC Menu Functions

Batch Length Configuration

Specifies batch length in hours or packs, accumulating statistics before reset.

Batch Start Time Setting

Synchronizes batch start to a specific time for hourly statistics, or disables facility if set to 00.00.

Batch Unit Selection (Time;Packs)

Selects batch interval units as TIME or PACKS. PEC must be fitted for PACKS.

Date and Time Configuration

Sets date and time for stamping contaminant, fault, and error logs, and printed reports.

Initiate Full Calibration

Accesses calibration options: Full Calibration, Update Calibration, or Man Setup.

Change Product Selection

Changes the currently running product by selecting from available options.

Clear Contaminant Log

Clears all entries from the contaminant log.

Clear Run Errors

Clears run errors, turning off error LED and relay if the error is no longer occurring.

Clear System Faults

Clears system faults, turning off fault LED and relay if the fault is no longer active.

Adjust Compensation Value

Adjusts compensation value, automatically derived during calibration, if advised by LOMA.

Machine Configuration Settings

Displays machine configuration details, typically adjusted during commissioning.

Contaminant Log Management

Allows viewing, clearing, and reporting of contaminant log entries.

Generate Contaminant Report

Transmits contaminant log details down the serial link, typically to a printer.

Reject Delay Time Setting

Sets the time for a contaminated product to travel from detector to reject point or PEC.

Disable Reject Mechanism

Disables the reject device so no product is rejected, even if contaminated.

Dry Product Mode Configuration

Configures detector for 'Dry' mode, useful for high vibration applications.

Reject Dwell Time Setting

Sets the time or distance the reject device is activated for contaminated products.

Enable Reject Mechanism

Re-enables the reject mechanism after it has been disabled.

Generate Run Error Report

Transmits the contents of the Run Error log down the serial link, typically to a printer.

False Threshold Configuration

Identifies metal test samples exceeding a specified false threshold value.

Generate System Fault Report

Transmits the contents of the System Fault log down the serial link, typically to a printer.

Ferrous Test Wand Size Setting

Sets the ferrous test wand size, prompted for during PV Test.

Product Flow Length Configuration

Defines the length of the product along the conveyor, allowing for skew.

Perform Full Calibration Procedure

Calibrates the detector for optimal performance using representative product samples.

View Good Packs Count

Shows the count of packs checked without metal since the current batch started.

Head Power Locking Control

Locks or unlocks the Head Power setting, preventing or allowing automatic adjustment.

Head Power Adjustment

Sets the head power automatically during calibration or manually if required.

PV Test Interval Setting

Specifies the time interval between automatic PV Test prompts.

ISC Threshold Limit Configuration

Configures minimum and maximum threshold limits for ISC operation.

Keyboard Lock Security

Locks the keyboard to prevent unauthorized access, defaulting display to signal level.

LOMA Service Menu Access

Menu typically used by LOMA service personnel for system diagnostics and settings.

View Machine Details

Displays machine software version and machine ID, which can be edited.

Manual Calibration Setup

Allows manual adjustment of calibration parameters set during commissioning.

Maximum Threshold Setting

Sets the maximum allowable threshold for product contamination detection.

Minimum Threshold Setting

Sets the lowest acceptable threshold to ensure adequate allowance for product variation.

Product Name Entry

Enters or edits the product name used in results and reports.