Loop-IP6820 Self Healing Ring NTU
Ethernet Access
6
Physical and Environmental
Dimensions 219 x 67.2 x 167 mm (HxWxD)
Temperature range
-10° to 50°C (commercial series), -20°C to 70°C (industrial series)
Humidity 0 to 95% RH (non-condensing)
Mounting DIN rail
Enclosure Type IP30 enclosure
Standards Compliance
IEEE
802.1d MAC Table Learning and STP 802.3u Fast Ethernet 100 Base-T
802.1p Priority Code Point 802.3x Flow Control
802.1q VLAN – port based VLAN and port
isolation
802.3z Gigabit Ethernet 1000 Base-T over
fiber optics
802.1s MSTP 802.3ab Gigabit Ethernet 1000 Base-T over
twisted pairs
802.1w RSTP 802.3ad Link Aggregation
802.1x* Port Access Protocol* 802.3af Power over Ethernet
802.1ad VLAN Tag Stacking (Q-in-Q) 802.3ah Ethernet in the First Mile
802.1ag Ethernet CFM 1588v2* Precision Time Protocol*
RFC (IETF) ITU
1112
IGMP Snooping v1
*
G.8032 v1/v2 Ethernet Ring Protection Switching
(ERPS)
2236
IGMP Snooping v2*
Y.1731 OAM
Loop Telecom
LEAPS* Each unit with 3.69 ms delay and 0.05 ms/km transmission delay (maximum)
Fault recovery time: less than 50 ms
Certifications
EMI/EMC FCC15 subpart B class A, EN55022 class A, EN55024, IEC61850-3*, IEEE1613*
Safety EN60950-1
*Future option
Panel Views
Front Panel View
Top Panel View
Oblique View