5
1. After the installation is complete:
a. Remove the aerator on the faucet (A).
b. Turn on the water supply and allow both
hot and cold water to run for at least one
minute each.
c. While the water is running, check for leaks.
d. Replace the aerator.
A
1
OPERATION INSTRUCTIONS
CARE AND MAINTENANCE
TROUBLESHOOTING
• Clean carefully by gently wiping with a grit-free damp cloth.
• Use only mild soap with water.
• Never use acids, harsh chemicals, or abrasive detergents to clean the faucet surface.
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
There is a leak under the handle. The cartridge is damaged. Remove the handle and replace
the cartridge, seats and springs.
There is an inconsistent water-
ow pattern.
The aerator is dirty or does not
t correctly on the faucet.
Unscrew the aerator and check
the rubber washer or replace
the aerator.
The spout/aerator has a leak. The cartridge is damaged. Remove the handle and replace
the cartridge.