Power Up: DLP-533 363-205-401
Page 4 of 6 Issue 7, March 1997
18.
!
DANGER:
A high discharge current is present at connector head if TESTING
indicator is lighted. Batteries must not be connected or disconnected
when TESTING indicator is lighted.
Battery pack is defective. Ensure that
TESTING
indicator is not lighted
(
READY
indicator lighted), unplug and set aside defective battery pack, and
repeat from Step
5.
19. Have
TIME
display and
STATUS
indicators been tested for each good
BATT
plug position?
If
YES,
then proceed to Step
21.
If
NO,
then continue with Step
20.
20.
!
DANGER:
A high discharge current is present at connector head if TESTING
indicator is lighted. Batteries must not be connected or disconnected
when TESTING indicator is lighted.
Ensure that
TESTING
indicator is not lighted (
READY
indicator lighted).
Unplug battery pack and repeat from Step
5.
21.
!
DANGER:
A high discharge current is present at connector head if TESTING
indicator is lighted. Batteries must not be connected or disconnected
when TESTING indicator is lighted.
Depress test set
START/CONTINUE
button.
22. Does test set
TESTING
indicator light,
READY
indicator go off, and
TIME
dis-
play start counting time?
If
YES,
then proceed to Step
24.
If
NO,
then continue with Step
23.