363-205-401 Acceptance: DLP-501
Issue 7, March 1997 Page 1 of 4
Perform Overall Visual Inspection of Remote
Terminal Equipment
1. If remote terminal (RT) is frame mounted, proceed to Step
7
.
2. Turn
MAIN
circuit breaker
ON
and verify AC power at convenience outlet(s). If
proper AC voltage is not present, resolve problem through local procedures.
3. Operate
MAIN
circuit breaker in transfer/breaker panel to
OFF
.
4. Verify that AC power into cabinet is correctly terminated on
MAIN
circuit
breaker. This can be accomplished by ensuring that AC power is not present
on the AC utility outlets in cabinet when the
MAIN
circuit breaker is in
OFF
position.
5. Is AC power present at utility outlets?
If
YES,
then continue with Step
6.
If
NO,
then proceed to Step
7.
6. Resolve problem through local procedures.
7. Measure resistance between ESD jack and known ground using DMM. Should
be < 1 ohm. If not < 1 ohm, then replace fan unit.
8. For dual RT channel bank assemble, verify that no plug-in units are installed.
(Remove any units that are installed.)
9. Verify that shelves are tightly secured and free of defects or damage. Resolve
problems through local procedures.
10. Verify that all electrical connectors inside of shelves are properly secured and
aligned with shelf slots. Resolve problems through local procedures.
11. Verify that there are no broken, bent, or misaligned contacts on front of con-
nectors. Resolve problems through local procedures.
12. Is one channel unit plug-in of any type available?
If
YES,
then continue with Step
12.
If
NO,
then proceed to Step
13.