363-205-401 Conversions: NTP-008
Issue 7, March 1997 Page 1 of 2
Add or Remove Protection Line Option
DO ITEMS BELOW IN ORDER LISTED FOR DETAILS, GO TO
SUMMARY:
The protection line is removed by removing the LSU and LIU-P and
setting the ADU protection line option (mini switch position 1 on S1 or S2) for no
protection. An LFU may be required if interfacing with a DDM-1000 or DDM-2000
multiplexer. The protection line is added by setting the ADU for the protection line
(mini switch position 1 on S1 or S2), optioning and installing the LSU and LIU-P LIU.
When changing the protection line equipage, both the RT and the CO equipment
must be changed.
1.
!
CAUTION:
When changing ADU protection equipage option, changing
any other mini switch position will cause service interruption.
Removing the ADU will interrupt service on digroup A if the
system is equipped for FPB Mode 1.
NOTE:
Changing protection line equipage option will cause an MN
alarm until changes at both ends are complete.
Remove the
ADU
and change mini switch position 1 on
S1
(AUB26 or AUB27) or
S2
(AUB22 or AUB24). Reinstall
ADU
.
2. If adding protection line proceed to Step
5
. If removing protection
line continue with Step
3
.
3. Remove
LSU
and
LIU
in
LIU-P
slot. Alarms will clear when both
ends make the changes.
4. If required, install
LFU
. Proceed to Step
8
.