Conversions: NTP-008 363-205-401
Page 2 of 2 Issue 7, March 1997
DO ITEMS BELOW IN ORDER LISTED FOR DETAILS, GO TO
5.
!
CAUTION:
The AUA73 LSU has a 32/64 option that must be set to 64
except for FPD applications.
DLP-511Install
LSU
.
6.
NOTE:
The LIU will have a CLF alarm and the ADU will have an MN
alarm until both ends are equipped for protection.
DLP-507Option and install
LIU
in
LIU-P
slot.
7. Exercise protection switching (
LSU f
mini switch
on
then
off
) for
each digroup. Replace
LSU
if any digroup will not switch.
8. Update office records.