Operating Manual Compact Weather Station
84 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
18.6.5.6 Buffer Assignment Additional Measurement Commands M6 / C6: Precipitation
Device configured for measurement values in metric units:
Measurement Value
UMB
Channel
Min
Max
Unit
Buffer ‘0’
Precip. Amount absolute
620
0.0
100000.0
Mm
Precip. Amount difference
625
0.00
100000.00
Mm
Precipitation Intensity
820
0.0
200.0
mm/h
Precipitation Type
700
0, 60, 70
Example: Request with M command
0M6!
00004<CR><LF>
0D0!
0+1324.5+1.10+4.4+60<CR><LF>
Device configured for measurement values in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Buffer ‘0’
Precip. Amount absolute
640
0.000
3937.000
In
Precip. Amount difference
645
0.0000
3937.0000
In
Precipitation Intensity
840
0.000
7.874
in/h
Precipitation Type
700
0, 60, 70