Operating Manual Smart Weather Sensor
102 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
19.6.4.10 Buffer Assignment Basic Data Set Power Saving Mode 2 (all Models)
Device configured for measurement in metric units:
Amount of Precip. Difference
Amount of Precip. Absolute
Wet Bulb Temperature (act)
*) Until device version .49 / .212 / Firmware v5.6: 1400.0 W/m
2
Example: Request Buffer ‘0’
0D0!
0+13.5+85.7+0.2+1017.0+1.8
Air temperature 13.5°C, rel. humidity 85.7%, precipitation 0.2°C, rel. air pressure 1017.0hPa, wind speed1.8m/s