Operating Instructions Smart Weather Sensor
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 83
Example: C Request from a WS600-UMB
0M!
000020<CR><LF> 20 measurement values are available
0D0!
0+13.5+85.7+1017+2.5+3.7<CR><LF>
air temperature 13.5°C, rel. humidity 85.7%, rel. air pressure 1017hPa
avg. wind speed 2.5m/s, max wind speed 3.7m/s.
0D1!
0+43.7+9.8+60+4.4<CR><LF>
wind direction 43.7° wet bulb temperature 9.C,
type of precipitation 60 (rain), precipitation intensity 4.4mm/h
0D2!
0+11.2+10.3+1.10<CR><LF>
dewpoint 11.2°C, wind chill temperature 10,3°C
diff. precipitation 1.10mm
0D3!
0+3.2+0.0+3.5+100.0<CR><LF>
act. wind speed 3,2m/s, min. wind speed 0.0 m/s
vect. avg. wind speed 3.5m/s, quality of wind values 100%
0D4!
0+43.7+41.3+45.7+29.3<CR><LF>
act. wind direction 43,7°, min. wind direction 41,3°,
max. wind direction 45,7°, specific enthalpy29,3kJ/kg