Hand pump with quick-disconnect-couplings:
12.2 Hydraulicuidrecommendation
12.1.4 Flow rates
NOTE:
The ow output per piston stroke of the hydraulic pumps depends exclusively
on the model series.
Model series
Flow output per piston
stroke (low pressure)
Flow output per piston
stroke (high pressure)
LH 2 / LF 2
17 [cm³] 1,7 [cm³]
0.85 [Cubic in.] 0.10 [Cubic in.]
Mineral oil DIN ISO 6743-4 for LUKAS hydraulic equipment and others
Oil temperature range Oil code Viscosity rating Remarks
A -20 .... +55°C HM 10 VG 10
Oil temperature range Oil code Viscosity rating Remarks
A -4.0 .... +131°F HM 10 VG 10
recommended viscosity range: 10...200 mm²/s (10…200 cSt.)
Supplied with HM 10 DIN ISO 6743-4.
ATTENTION!
Before using hydraulic uids that do not correspond to the aforementioned
specications and / or are not purchased from LUKAS, you must contact
LUKAS!
Tank size Dimensions Weight min. required
l x w x h
(incl. max. hydraulic
uid ll level)
Fill quantity
1,8 [l]
724 x 200 x 160 [mm] 7,3 [kg] 2,38 [l]
28.96 x 7.87 x 6.30 [in.] 16.1 [lbs.] 0.63 [gal.-US]
3,8 [l]
740 x 200 x 160 [mm] 11,6 [kg] 4,61 [l]
29.13 x 7.87 x 6.30 [in.] 25.6 [lbs.] 1.22 [gal.-US]
Foot pump LF2 with quick-disconnect-couplings:
Tank size Dimensions Weight min. required
L x W x H
(incl. max. hydraulic
uid lling level)
llingquantity
1.8 [l]
740 x 225 x 176 [mm] 10,0 [kg] 2,38 [l]
29.13 x 8.86 x 6.93 [in.] 22.05 [lbs.] 0.63 [gal.-US]