2-4
CDA3000 Operation Manual
2 Mechanical installation
2.4 Cold plate
Figure 2.2 Mounting clearances (see Table 2.3)
Step Action Comment
1
Mark out the positions of the tapped
holes on the backing plate or the cooler.
Cut a tap for each fixing screw in the
backing plate.
Dimensional drawings/hole
spacing - see Table 2.3.
The tapping area will provide
you with good, full-area contact.
2
Clean the contact surface and coat it
thinly and evenly with heat transfer
compound.
The contact surface must be
metallically bright.
3
Mount the inverter module vertically on
the backing plate or cooler. Tighten all
screws to the same tightness.
Pay attention to the mounting
clearances! Size of cooling area
- see Table 2.4.
4
Mount the other components, such as
the mains filter, line choke etc., on the
backing plate.
Mains filter max. 20 cm below
the inverter module
5
Continue with the electrical installation in
section 3.