Four Mounting Holes
Diameter - 0.25 in. (6mm)
Four Screws
Secure Cover
6.10 in.
(155 mm)
3.30 in.
(84 mm)
12.50 in.
(318 mm)
Wall
11.75 in.
(298 mm)
4.0 in.
(102 mm)
COOPERSBURG, PA 18036 U.S.A.
G 2 CB
144-317 Rev. 1.9
0-10V INTERFACE CONTROL
Control Input:
100-120V
, 220-240V 50/60Hz
Switched Output: 100-277
GRX-TVI
Incandescent
16A
Fluorescent
5A
Magnetic Low-voltage
16A
Electronic Low-voltage 16A
Neon/Cold Cathode 16A
Motor
1/4 HP@120V
1/2 HP@277V
®
Control
GRX-TVI Input Rating
I
H
2
0.02A
I
DH
2
0.1A
Load T
ype Switched
Ratings
®
10A
5AX
10A
10A
10A
Control
GRX-TVI Input Rating
I
H
2
0.02A
I
DH
2
0.1A
Load Type Switched
Ratings
ACN
003 715 277
0-10V Output Rating
Max. 0.3A PELV
0-10V Output Rating
Max.
0.3A Class 2
Switched µ
Instructions d’installation et de fonctionnement
A lir
e avant de procéder à l’installation
Exemplaire utilisateur
Interface de commande GRX-TVI
Contrôle de phase 0-10V
Description
La GRX-TVI offre un contrôle et une commutation de ballast 0-10V
dans un seul boîtier. L’unité GRX-TVI permet aux unités de commande
GRAFIK Eye de la série 3000 de contrôler des ballasts 0-10V
alimentés en 100V à 277V (
le ballast doit fournir une source de
courant de 0 à 10V
) et offre des relais de commutation permettant
de gérer les à-coups de courant d’un circuit de ballasts. La GRX-TVI
permet aux unités de commande
GRAFIK Eye de la série 3000 à la fois
de faire varier et de commuter des ballasts électroniques comme
l’Eco-10
de Lutron (modèles TVE). L’interface GRX-TVI peut
également être utilisée pour commuter n’importe quel type de charge
indiqué ci-dessous.
Note: Si une unité de commande GRAFIK Eye Série 3000 est utilisée, il faut
une interface GRX-TVI pour chaque zone fluorescente de 0-10V.
(Par exemple : une commande à 3 zones avec deux zones
fluor
escentes et une zone incandescente.)
Montage
Trouver un emplacement adapté pour le montage.
n Choisir l’emplacement adéquat pour installer l’inter
face GRX-TVI
(enceinte NEMA T
ype 1 utilisation à l’intérieur exclusivement).
Voir le schéma de câblage du système ci-dessous.
n L’environnement d’installation de l’unité GRX-TVI doit présenter une
plage de température ambiante de 0—40 °C.
n Fixer le boîtier verticalement au mur (vis non fournies).
Voir schéma de montage ci-dessous.
n La méthode de montage doit permettre de résister au poids et aux
forces appliquées en cours d’installation.
n Les relais internes font entendre des cliquetis lorsqu’ils sont en
fonctionnement — veiller à monter ces éléments où le bruit audible
est acceptable.
Schéma de câblage du système
Schéma de montage
Spécifications des produits
Quatre Trous DEmontage
Diamètre: 0,25 in. (6 mm)
Q
uatr
e
V
is
AS
sur
ent
LAfixation du couvercle
12,5 in.
(318 mm)
3,30 in.
(84
mm
)
6,10 in.
(155
mm
)
LUTRON
LUTRON
LUTRON
COMMANDE D
e zone Fluorescente 0-10V/Charge 1
COMMANDE D
e zone Fluorescente 0-10V/Charge 1
Ballast 0-10V
Alimentation
provenant
de l’armoire
de
distribution
GRX-
TVI
GRX-
TVI
B
allast
Zone Fluorescente
Commutée/Charge 2
Zone Iincandescente/Charge 3
UNITÉ DE Commande
Commandes
MURALES Basse Tension de 1 mm2/pelv
B
allast 0-10V
COOPERSBURG,
PA 18036 U.S.A.
G 2 CB
144-317 Rev. 1.9
0-10V INTERFACE CONTROL
Control Input:
100-120V, 220-240V 50/60Hz
Switched Output: 100-277
GRX-TVI
Incandescent 16A
Fluorescent 5A
Magnetic Low-voltage 16A
Electronic Low-voltage 16A
Neon/Cold Cathode 16A
Motor 1/4 HP@120V
1/2 HP@277V
®
Control
GRX-TVI Input Rating
I
H
2
0.02A
I
DH
2
0.1A
Load Type Switched
Ratings
®
10A
5AX
10A
10A
10A
Control
GRX-TVI Input Rating
I
H
2
0.02A
I
DH
2
0.1A
Load Type Switched
Ratings
ACN
003 715 277
0-10V Output Rating
Max. 0.3A PELV
0-10V Output Rating
Max. 0.3A Class 2
Switched µ
4,0 in.
(102 mm)
11,75 in.
(298
mm)
MUR
100-127V/
200-277V
230V
(
CE
)
CARACTERISTIQUES
...Fournit un signal de sortie basse tension de 1 mm2/PELV
isolé de 0-10V conforme aux normes EN60929 et IEC60929.
Accepte un signal de commande fluorescent constant
(100-127V, 220-240V, 50/60Hz).
ALIMENT
ATION
.............................
100-127/220-240V, 50/60Hz
BORNE H2/L2 ...............................20mA
ENTREE
BORNE DH2/DL2
...........................100mA
ENTREE
SORTIE 0-10V
...............................10µA-300mA – Génère uniquement du courant
(maximum 150 ballasts)
Type de source/charge
Fluorescent
Eco-10
de Lutr
on
T
(série TVE)
Electronique capacitive
Sans gradation
Ballasts 0-10V d’autr
es fabricants
(source de 0-10V uniquement)
Incandescent
Basse tension
Iodure métallique
Néon/cathode fr
oide
16A
16A
16A
16A
16A
16A
16A
10A
10A
10A
10A
10A
10A
Moteurs 1/4HP @ 100-120V
1/2HP @ 200-277V
1/2HP @ 230V CE
BORNES Deux conducteurs 0,5-2,5 mm
2
(#12-20AWG) par borne.
MONTAGE Boîtier NEMA Type 1 utilisation à l’intérieur exclusivement.
ENVIRONNEMENT 32—104 ˚F (0—40 ˚C).