#46
For Your Information ...
APPLICATION
NOTE
Overview
Using the RadioRA
®
Telephone Interface
Wiring
The RadioRA® System can now be controlled from any location worldwide by using the RadioRA Telephone Interface (RA-
RC-3). The Telephone Interface allows for activation of scenes programmed to a RadioRA Switch Closure Interface (RA-SCI)
via telephone. By connecting the three (expandable to nine) outputs from the Telephone Interface to the inputs of the RA-
SCI, pressing buttons on any telephone will turn lighting scenes ON/OFF.
The wiring diagram below shows how to wire up three outputs from the RadioRA Telephone Interface (RA-RC-3) to the
inputs of a RadioRA Switch Closure Interface (RA-SCI). The RA-RC-3 and RA-SCI can then be programmed as described
on the following page to activate the desired scenes. For this application, RA-SCI inputs must be set up for MOMENTARY
operation. A dedicated phone line is not required, but is recommended.
* The RA-RC-3 monitors for DTMF tones anytime the phone line is in an off-hook condition. This allows for its use in conjunction with an
answering machine.
After wiring as above, proceed to programming on the following page. To have additional information faxed to you concerning
the Telephone Interface, call 715-386-4345 and request document #165.
Coopersburg, PA USA
TM
Power
Program
Closure
Type
Input
Select
Momentary LED
Maintained LED
Full
Flash
Input 1
Input 2
Input 3
Input 4
Input 5
Common
Input 1
Input 2
Input 3
Input 4
Input 5
See the Switch Closure Interface Addendum to the Programming
Guide for operating instructions.
For additional assistance call the
Lutron Technical Assistance
Hotline:
1-800-523-9466
FCC ID JPZ0005
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference and (2) This device must accept any
interference received including interference that may cause undesired operation.
ON
Button LED
Patents Pending
Switch Closure Input Interface
AC IN
Full
Flash
Input 1
Input 2
Input 3
Input 4
Input 5
Common
Class 2
connection only
Switch Closure
Interface
Model No.
RA-SCI
Common
Scene 3
Scene 2
Scene 1
Talk Battery
Relay 1
CNO
Relay 2
CNO
Relay 3
CNO NC A - +
ONOFF
To 12 VDC
Transformer (Supplied)
To C. O. telephone line
To in house phones* or
additional RA-RC-3
Terminals
Telephone Interface
Model No.
RA-RC-3
Close-up
of RA-RC-3
Terminals
To AC
Transformer
(Supplied)
12345678910
RJ-IN RJ-OUT
12VDC
Not used
for this
application
To additional
RA-RC-3 units
(if used)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lutron Electronics RadioRA RA-RC-3 and is the answer not in the manual?

Lutron Electronics RadioRA RA-RC-3 Specifications

General IconGeneral
BrandLutron Electronics
ModelRadioRA RA-RC-3
CategoryRecording Equipment
LanguageEnglish

Related product manuals