INSTRUCTION MANUAL
UNIVERSAL TRANSMITTER
(eld- and PC-congurable)
MODEL
M3LU
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
Terminal block with CJC sensor ........................................(1)
I/O range and tag name label sheet ...................................(1)
MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures. For detailed information,
refer to the operating manual (EM-2652-B).
The M3LU with Option A is programmable using the PC
configurator software. For detailed information on the PC
configuration, refer to the M3LUCFG instruction manual.
The M3LUCFG PC Configurator Software and operating
manual are downloadable at M-System’s web site: http://
www.m-system.co.jp.
POINTS OF CAUTION
CONFORMITY WITH UL
This equipment is suitable for use in a Pollution Degree
2 environment.
DO NOT connect the thermocouple or the RTD to circuits
greater than 30Vrms and 42.4Vpeak or 60V DC.
This equipment is to be used with the maximum operat-
ing voltage 30Vrms and 42.4Vpeak or 60V DC.
The equipment must be mounted inside a suitable fire
enclosure.
Operating temperature: -25 to +55°C (-13 to +131°F)
CONFORMITY WITH EU DIRECTIVES
This equipment is suitable for Pollution Degree 2 and In-
stallation Category II (transient voltage 2500V). Rein-
forced insulation (signal input or output to power input:
300V) and basic insulation (signal input to output: 300V)
are maintained. Prior to installation, check that the insu-
lation class of this unit satisfies the system requirements.
Altitude up to 2000 meters.
The equipment must be mounted inside a panel.
Insert a noise filter for the power source connected to the
unit. TDK-Lambda Noise Filter Model RSAN-2006 or
equivalent is recommended.
The equipment must be installed such that appropriate
clearance and creepage distances are maintained to con-
form to CE requirements. Failure to observe these re-
quirements may invalidate the CE conformance.
The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
Install lightning surge protectors for those wires connect-
ed to remote locations.
POWER INPUT RATING & OPERATIONAL RANGE
Locate the power input rating marked on the product and
confirm its operational range as indicated below:
100 – 240V AC rating: 85 – 264V, 47 – 66 Hz, approx. 4 – 6VA
10 – 32V DC rating: 9 – 36V, approx. 2W
GENERAL PRECAUTION
Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
ENVIRONMENT
Indoor use.
When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
Environmental temperature must be within -25 to +65°C
(-13 to +149°F) with relative humidity within 0 to 95%
RH in order to ensure adequate life span and operation.
Be sure that the ventilation slits are not covered with ca-
bles, etc.
WIRING
Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
AND ....
The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.