9 CHARGE PROFILE CHANGE PROCEDURE
!
WARNING: This charger may be provided with a manual selectable charge profile feature that
allows for the proper charging of:
(W) = Wet gassing lead acid batteries
or
(S) = Sealed valve regulated (SVR), gelled/agm type lead acid batteries
Verify charge profile setting after charge begins. A flashing incomplete LED prior to the 80% LED
coming on indicates a (S) sealed valve regulated profile has been selected. If not flashing, charger
is in a (W) wet charging profile.
NOTE: Any chargers having a circuit with date code 9719 or earlier did not incorporate this flashing
LED feature.
!
CAUTION: Improper profile setting may damage the batteries. To change setting remove cover
and follow instructions in charger.