Intrinsically Safe ERX display (Flow Indicator/Totalizer) Type (Fx)
Macnaught type Fx display uses:
Fluidwell Intrinsically Safe display electronic PN: F012-P-HR-PC-PD-XI-ZB
Wiring Instructions reference
www.fluidwell.com/assets/downloads/Manuals/FW-F012-P-M_v0404_01_EN.pdf?
Use this Instructions Manual if further details are required
Type Fx is an Intrinsically Safe digital register with a 17mm LCD display,
providing real-time indication of Flow rate, total (resettable) and accumulat-
ed total (non-resettable).
This display is IECEx, ATEX, CSA Canada and FM USA certified.
Locally mount to Macnaught Oval Gear Flowmeter with a Simple Apparatus
PCB
The flowmeter with Simple Apparatus PCB and Intrinsically Safe display is
IP67 rated
Ensure that the measuring system is correctly wired up according to the wiring diagrams. The housing may only
be opened by trained personnel
This product cannot be repaired by the user and must be replaced with an equivalent certified product. Repairs
should only be carried out by the manufacturer or his authorized agent.