Page 18 of 32
MX06-MX50: Serial number, Model number, k-factor,
flow rate range and temperature details are
engraved on meter body. See below FIG
MX75-MX100: Serial number, Model number,
k-factor, flow rate range and temperature details are
engraved on flow meter data plate. See below FIG
Flow meter Specs / Data Plate
Meter Lock Nut Torque ANSI / ASTM DIN JIS End to End
MX25 20 Nm 1" 150 LB B16.5 DN25 PN 16 EN1092-1 25A 10K JIS B 2220 240 mm
MX40 30 Nm 1.5" 150 LB B16.5 DN40 PN 16 EN1092-1 40A 10K JIS B 2220 240 mm
MX50 40 Nm 2" 150 LB B16.5 DN50 PN 16 EN1092-1 50A 10K JIS B 2220 264 mm
1. The locknut, gasket, O-ring and retaining ring to be fitted as shown in the below picture. Make sure that the
O-rings and gaskets must not have any damages.
2. Both flanges to be equally screwed to the meter body meeting end to end dimensions and bolt pattern on
the flange face
3. The lock nuts to be tightened to a specified torque as mentioned in the below table
Use a good quality grease for Gasket & O-ring and a good quality anti-cease on flange threads
INSTALLATION OF FLANGES ON MX25, MX40 AND MX50 METERS
Flow Meter Details
Flow Meter Details
Flow Meter Details