EasyManua.ls Logo

Magellan MG-6130 User Manual

Magellan MG-6130
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
All-In-One Wireless Security System V2.0
Programming Guide
Model # MG-6130 / MG-6160
We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit
www.paradox.com and send us your comments.
Table of Contents
Things You Should Know..................................... 2
About This Programming Guide........................................... 2
Conventions......................................................................... 2
Installer Code (Default: 0000 / 000000)............................... 2
Maintenance Code (Default: 1111 / 111111)....................... 2
Master Code (Default: 1234 / 123456)................................. 2
Entering Programming Mode ............................... 2
Single Digit Data Entry Method............................................ 2
Feature Select Programming Method.................................. 3
Decimal and Hexadecimal Values ....................................... 3
Installer Quick Keys .............................................. 3
Zone Programming................................................ 4
Remote Control Button Programming................. 5
System Timers....................................................... 6
On-board Programmable Outputs (PGMs).......... 6
System Options ..................................................... 7
Communicator Settings ..................................... 10
Report Codes....................................................... 11
System Settings................................................... 13
Wireless Transmitter Assignment...................... 13
Wireless Output Assignment .............................. 14
Wireless Keypad Assignment............................. 14
Wireless Repeater Assignment........................... 14
Wireless Programmable Output (PGM) Settings 14
Wireless Supervision Options ............................ 14
Wireless Repeater Options.................................. 16
Appendix 1: PGM Event Table ............................ 18
Appendix 2: Specifications ................................. 20
Appendix 3: Connection Diagrams..................... 21
Power Connections........................................................... 21
Telephone Line Connections ............................................ 22
PGM Connections............................................................. 23
Hardwire Zone Connections.............................................. 24
Connecting the Radio Antenna (MG-6160 only) ............... 24
Connecting to a UIP-256................................................... 25
X10 Transmitter Connections (MG-6160 only).................. 25
Connecting Magellan to WinLoad ..................................... 26
Connecting a Paradox Memory Key (PMC-4)................... 26
Tabletop Mounting ............................................................ 27
Mounting Magellan on the Wall......................................... 27
Appendix 4: Ademco Contact ID Report Codes 28
Appendix 5: Automatic Report Code List .......... 30
Question and Answer IconNeed help?

Do you have a question about the Magellan MG-6130 and is the answer not in the manual?

Magellan MG-6130 Specifications

General IconGeneral
BrandMagellan
ModelMG-6130
CategorySecurity System
LanguageEnglish

Summary

Entering Programming Mode

Zone Programming

Zone Definitions

Defines zone types like Entry Delay, Instant, Fire.

Zone Options

Configures zone attributes like bypass, alarm type, Intellizone.

Remote Control Button Programming

Button Options Table

Lists available functions for remote control buttons.

System Timers

Entry Delay 1 Timer

Sets the duration for the first entry delay.

On-board Programmable Outputs (PGMs)

System Options

General Options [090] Configuration

Configures access code length, tamper, PGM states.

Zone Options [094] Configuration

Configures zone delay, tamper, and supervision.

Dialer Options [098] Configuration

Configures telephone line monitoring and dialing.

General Options [091] Configuration

Configures panic buttons and PGM usage (X10).

Arming/Disarming Options [092] Configuration

Configures auto-arm, stay arming, force arming.

Communicator Settings

Report Format for Monitoring Station Telephone Number 1

Selects the report format for the primary monitoring number.

Report Format for Monitoring Station Telephone Number 2

Selects the report format for the secondary monitoring number.

Account Number Configuration

Enters the account number for the monitoring station.

Monitoring Station Telephone Number 1 Configuration

Sets the primary telephone number for the monitoring station.

Monitoring Station Telephone Number 2 Configuration

Sets the secondary telephone number for the monitoring station.

Report Codes

Tamper Report Codes by Zone

Codes for tamper events categorized by zone.

Tamper Restore Report Codes by Zone

Codes for tamper restore events categorized by zone.

System Trouble Report Codes

Codes for system trouble events.

Alarm Report Codes by Zone

Codes for alarm events categorized by zone.

System Troubles Restore Report Codes

Codes for system trouble restore events.

Alarm Restore Report Codes by Zone

Codes for alarm restore events categorized by zone.

System Settings

Installer Code Setting

Procedure to set or change the installer code.

Wireless Transmitter Assignment

Zone 1 Serial Number Assignment

Assigns the serial number to the Zone 1 transmitter.

Zone 2 Serial Number Assignment

Assigns the serial number to the Zone 2 transmitter.

Wireless Output Assignment

Wireless Keypad Assignment

Wireless Repeater Assignment

Wireless Programmable Output (PGM) Settings

Wireless PGM1 Activation Event Configuration

Configures the event that triggers Wireless PGM1 activation.

Wireless Supervision Options

Zone 1 Supervision Configuration

Enables or disables supervision for Zone 1.

Zone 2 Supervision Configuration

Enables or disables supervision for Zone 2.

Wireless Transmitter Supervision Zone Options

Zone 9 Supervision Configuration

Enables or disables supervision for Zone 9.

Zone 17 Supervision Configuration

Enables or disables supervision for Zone 17.

Zone 25 Supervision Configuration

Enables or disables supervision for Zone 25.

Wireless PGM Supervision Options

Wireless Keypad Supervision Options

Wireless Repeater Supervision Options

Wireless PGM Console Supervision Options

Wireless Repeater Options

Repeat Wireless Zone 1 Signals Configuration

Repeats signals for Wireless Zone 1.

Repeat Wireless Zone 25 Signals Configuration

Repeats signals for Wireless Zone 25.

Repeat Wireless Zone 9 Signals Configuration

Repeats signals for Wireless Zone 9.

Repeat Wireless Zone 17 Signals Configuration

Repeats signals for Wireless Zone 17.

Appendix 1: PGM Event Table

Zone in Alarm Event Group

Defines the event group for a zone in alarm.

Appendix 2: Specifications

Backup Battery Specification

Details the type and requirements for the backup battery.

Appendix 3: Connection Diagrams

AC Transformer Connection Diagram

Illustrates the connection of the AC power transformer.

PGM1 Connections Diagram

Illustrates various connection methods for PGM1.

Hardwire Zone Connections Diagram

Illustrates different hardwire zone configurations.

Telephone Line Direct Connect Diagram

Illustrates the direct connection of the telephone line.

PGM2 Connections Diagram

Illustrates various connection methods for PGM2.

Backup Battery Connection Diagram

Illustrates the installation of the backup battery.

Appendix 3: Connection Diagrams

Mounting Magellan on the Wall

Wall Plate Mounting Procedure

Steps to mount the wall plate to the wall.

Magellan Console Wall Mounting Procedure

Steps to mount the console onto the wall plate.

Appendix 4: Ademco Contact ID Report Codes

Fire Alarms Report Codes (110)

List of Ademco Contact ID report codes for fire alarms.

Panic Alarms Report Codes (120)

List of Ademco Contact ID report codes for panic alarms.

Burglar Alarms Report Codes (130)

List of Ademco Contact ID report codes for burglar alarms.

System Troubles Report Codes (300-310)

List of Ademco Contact ID report codes for system troubles.

Communication Troubles Report Codes (350-360)

List of Ademco Contact ID report codes for communication troubles.

Sensor Troubles Report Codes (380-390)

List of Ademco Contact ID report codes for sensor troubles.

Appendix 5: Automatic Report Code List

Zone Alarm Report Code

Report code for zone alarm events.

Emergency Panic Report Code (Panic 1)

Report code for emergency panic (Panic 1).

Module Fail to Communicate Report Code

Report code for module communication failure.

Fail to Communicate with Monitoring Station Report Code

Report code for communication failure to station.

UL AND ULC WARNINGS

UL and C-UL Installation Notes

Guidelines for installing the system to meet UL/ULC standards.

Related product manuals