Rated Watts | 5500 |
---|---|
Starting Watts | 6875 |
Fuel Type | Gasoline |
Displacement | 389cc |
Starting System | Recoil |
Fuel Tank Capacity | 6.6 Gallons |
Weight | 165 lbs |
Engine Type | 4-Stroke OHV |
AC Output | 120/240V |
DC Output | 12V |
Outlet Types | 4 x 120V 20A Outlets, 1 x 120/240V Twist-Lock Outlet, 1 x 12V DC Outlet |
Company contact details, address, phone, fax, and website for support.
Warning regarding diesel engine exhaust constituents and their known effects.
Explains the use of the safety alert symbol for potential personal injury hazards.
Defines DANGER, WARNING, CAUTION, and NOTICE levels for hazard communication.
Optional light for illuminating the control panel for better visibility.
The primary controller for starting, stopping, and monitoring generator and engine functions.
Switch to operate the optional control panel light.
Switch to operate the optional interior light within the generator enclosure.
Breakers that disconnect power to the 120V GFCI outlets.
Breakers that disconnect power to the 120/240V twist-lock outlets.
Connection point for a remote start switch or dry-contact closure for remote operation.
Outlets for connecting additional loads or equipment to the generator.
Outlets providing ground fault circuit interrupt protection for connecting loads.
Connection point for powering battery chargers and other engine accessories.
Terminal for connecting the generator to a proper earth ground for safety.
Points for directly wiring external loads to the generator's output.
Optional receptacles for connecting loads using series 16 taper nose cam locks.
Switch to change generator output voltage connections between output leads and lugs/cam locks.
Primary breaker that disconnects power to connection lugs and cam locks.
Describes the various controls and displays of the MDC, including operation, diagnostics, and status indicators.
Displays engine oil pressure readings and normal operating ranges.
Shows engine coolant temperature and shutdown thresholds.
Indicates the fuel level percentage and low fuel warning/shutdown points.
Displays the engine battery voltage when the unit is running.
Explains how to navigate through "Running", "Password", and "History" screens on the MDC.
Lists and explains the codes displayed by the MDC for generator operational states.
Detailed table of shutdown and warning fault conditions and their corresponding messages.
Steps to troubleshoot and resolve shutdowns due to low fuel levels.
Steps to troubleshoot and resolve shutdowns caused by low engine oil pressure.
Troubleshooting steps for shutdowns resulting from insufficient engine coolant.
Troubleshooting steps for shutdowns caused by excessive engine coolant temperature.
Common causes and troubleshooting for the engine failing to start within the allowed crank cycles.
Guidance on resolving shutdown conditions related to engine overspeed or underspeed.