3) Battery
Cause Remedies
1. Frequently insufficient electric power
Breakdowns of generator or regulator
or no charging electric current
Repair generator or regulator
Loosened connecting wires of charging
circuit or rust making resistance increase
Check to see whether terminals and bolts
of connecting wires are loose or not and
tighten them, or remove rust
Short circuit of plate Check and repair
2. Automatically discharging of battery,
too high impurity content of plate material
or impure electrolyte
2. Completely discharge battery or
overdischarge battery to make plate
impurity enter electrolyte then pour
electrolyte out and clean with distilled water,
and refill with new electrolyte and recharge
3. Charge capacity of battery distinctively
reduces (low discharging voltage, high
charging voltage, low indensity of
electrolyte and plates sulphurized)
Frequently insufficient electric power
Charge for a long time with small electric
current or completely charge and completely
discharge repeatedly
Discharge in small electric current for a
long time and not charging in time
Make activated material restore. Or
charge with sulphre removal method
Too low of electrolyte lever, upper part
of plate emerging from electrolyte lever
Replenish electrolyte