14. Performance optimization
Performance optimization is a process that informs the
appliance about its installation/working conditions so that it
can adjust itself accordingly. The appliance is thus more
responsive.
14.1) Set the main switch to position O (off).
14.2) On the control unit front panel, place the rotary
temperature control knob at position ‘45’.
14.3) Press and hold the burner indicator button (Fig 3,
key13) and set the main switch to position I (on). The
green burner indicator button blinks.
The appliance is now in performance optimisation mode.
14.4) Fully open a hot water tap.
14.5) Operate the appliance for approximately 5 minutes.
14.6) Set the main switch to position O (off).
Close the hot water tap and set the main switch back to
position I (on).
The performance optimisation operation is complete.
Fig. 23