7. Siting the Appliance
7.1 The appliance is NOT suitable for external installation.
7.2 The appliance is NOT suitable for SEDUCT
application.
7.3 The appliance does not require any special wall
protection.
7.4 The wall must be capable of supporting the weight of
the appliance. See Technical Data Table 1.
7.5 If the appliance is to be fitted in a timber framed
building, refer to the Institute of Gas Engineers, ”Guide
for gas installations in timber framed housing” IGE/UP/7.
7.6 The following advisable clearances must be available
for installation and for servicing:
7.7 The minimum clearances required for Operation are:
7.8 The appliance can be installed in a cupboard used
for airing clothes provided that requirements of BS 6798
and BS 5440:2 are strictly followed. See section 9 for further
detail.
7.9 The airing space must be separated from the appliance
space by a perforated non-combustible partition. Expanded
metal or rigid wire mesh are acceptable provided that the
major dimension is less than 13 mm.
See BS 6798
Table 4
Above case 120 mm
In front 600 mm
Below 50 mm
Ri
g
ht hand side 10 mm
Left hand side 10 mm
Table 5
Above case 120 mm
In front 60 mm
Below 50 mm
Ri
g
ht hand side 10 mm
Left hand side 10 mm