Installation and Operating
Instructions

     
    

         


 
 
 

 

 

 
 


       



       


          
       


 





53D0419 3/09 Rev. 10
420200
6000DV cover














    




Questions and Answers

  • P
    Philip MillerAug 9, 2025
    Why Majestic Indoor Fireplace spark ignitor will not light pilot?
    • W
      wbutlerAug 9, 2025
      If the spark ignitor of your Majestic Indoor Fireplace won't light the pilot after repeatedly triggering the piezo, there are several possible reasons. First, check that the wire is connected to the ignitor. If the wire is connected, the ignitor may be defective. Check for a spark at the electrode and pilot; if there's no spark and the electrode wire is properly connected, replace the pilot assembly. Another possibility is that there's no gas or low gas pressure. Check the remote/manual shut-off valve from the fireplace. Low pressure can be caused by bent or restricted lines, or generally low pressure. Finally, check the Propane/LPG tank to ensure it is not empty and refill it if necessary.
  • H
    hernandezerinAug 21, 2025
    How to fix Majestic Indoor Fireplace pilot that won't stay lit?
    • J
      Johnny KellyAug 21, 2025
      If the pilot of your Majestic Indoor Fireplace won't stay lit after carefully following the lighting instructions, it might be due to a defective thermocouple. Ensure that the pilot flame impinges on the thermocouple. Clean and/or adjust the pilot for maximum flame impingement. Also, make sure the thermocouple connection at the gas valve is fully inserted and tight. To test the thermocouple, disconnect it from the valve and place one millivolt lead wire on the tip of the thermocouple and the other meter lead wire on the thermocouple copper lead. Start the pilot and hold the valve knob in. If the millivolt reading is less than 15 mV, replace the pilot assembly. If the thermocouple is producing more than 15 mV, the valve may be defective and needs replacement.
  • M
    Mark AndersonOct 30, 2025
    What to do if Majestic Indoor Fireplace burner will not ignite?
    • B
      bushcharlesOct 31, 2025
      If the pilot is burning, the valve knob is set to 'ON', and the switch is also set to 'ON' or 'RS', but the burner of your Majestic Indoor Fireplace won't ignite, there are several potential causes. It could be a defective switch, wall switch, remote control, or wiring. Check the switch and wiring for proper connections. You can use jumper wires across the switch terminals; if the burner starts, the switch is defective and needs replacement. If the switch is fine, repeat this process on the remote control. If the burner then comes on, replace the remote control. Alternatively, place a jumper wire across the wire at the gas valves (terminals marked TH and TP/TH). If the burner ignites, the wires are faulty or have bad connections and should be replaced. Another cause might be that the pilot...

Summary

Important Safety Information

General Safety Precautions

Essential safety warnings covering gas leaks, high temperatures, children, and flammable materials.

Installation and Operational Safety Guidelines

Installation and Operational Safety Guidelines

Safety rules for installation, material use, electrical grounding, and operational conduct.

Pre-Installation Information

Site Considerations and Gas Specifications

Information on high elevations, orifice sizes, gas pressures, and BTU ratings.

Installation and Operating Instructions

Fireplace Location Guidelines

Recommendations for safe placement, avoiding traffic, and supervising children.

Clearances and Finishing

Clearances to Combustible Materials

Requirements for maintaining safe distances from flammable surfaces and materials.

Vent Installation Requirements

Vent System Installation Precautions and Warnings

Essential safety rules, warranty considerations, and approved venting system usage.

Vent Installation Clearances

Combustible Clearances for Vent Pipe Configurations

Diagrams and specifications for vent pipe clearances to combustible materials.

Vent Installation Planning

Horizontal Vent Termination Details

Minimum Distances and Clearance Requirements

Detailed minimum clearance measurements for horizontal vent terminations to various building elements.

Vent Termination Clearances and Graph Usage

Rear Wall Vent Installation

Vent Opening and Pipe Connection Requirements

Procedures for creating openings and connecting vent pipes for rear wall terminations.

Rear Wall Vent Installation Continued

Horizontal Termination Configurations

Below Grade Vent Installations

Vertical Through-the-Roof Applications

Vent Height, Elbows, and Roof Penetration

Requirements for vertical vent installations, including height, elbows, and roof flashing.

Vertical Termination Installation

Fireplace Installation and Gas Supply

Gas Type Verification and Piping Installation

Ensuring correct gas type and guidelines for installing gas piping and regulators.

Propane;LP Gas Connection Requirements

Specific instructions for connecting propane/LP gas, including regulator use and pressure reduction.

Fireplace Gas Connection

Gas Pressure and Electrical Installation

Checking Gas Pressure and Adjusting Flame Height

Procedures for verifying gas pressure, adjusting burner flame, and leak testing.

Electrical Wiring and Safety

Guidelines for safe electrical connections, grounding, and compliance with codes.

Electrical Installation Details

Log Placement Instructions

Operating Instructions: Lighting Procedures

Safety Before Lighting and Gas Leak Checks

Crucial safety steps before lighting and procedures for detecting gas leaks.

Initial Pilot Lighting and Leak Testing

Steps for purging air, lighting the pilot, and testing for gas leaks.

Pilot Lighting Procedures

Approved Leak Testing Methods and Pilot Lighting Steps

Valid leak testing techniques and detailed instructions for lighting the pilot.

Burner Operation

Main Burner Switch and Lighting Procedure

How to use the main burner switch and light the burner for operation.

Troubleshooting: Standing Pilot Ignition

Common Pilot Ignition Issues and Solutions

Troubleshooting guide for spark ignitor, pilot lit, and burner ignition problems.

Troubleshooting: Electronic Ignition

Electronic Ignition System Fault Diagnosis

Flowchart for diagnosing issues with the electronic ignition system.

General Troubleshooting and Blower Accessory

Limited Lifetime Warranty Policy