7
Range Resolution Accuracy
200.0mV 0.1mV ±0.5% of rdg ±2 dgts
2.000V 1mV
±1.2% of rdg ±2 dgts
20.00V 10mV
200.0V 100mV
600V(CAT III) 1V ±1.5% of rdg ±2 dgts
1000V(CAT II) ±1.5% of rdg ±4 dgts
5.1. DC Voltage (Auto Ranging)
Input Impedance: 10MΩ.
Maximum Input: 600V DC/AC RMS.(CATIII)
Maximum Input: 1000V DC/AC RMS.(CATII)
Range Resolution Accuracy
200.0mV 0.1mV ±1.5%of rdg ±30 dgts
2.000V 1mV ±1.2% of rdg ±3 dgts
20.00V 10mV
±1.5% of rdg ±3 dgts
200.0V 100mV
600V(CAT III) 1V ±2.0% of rdg ±4 dgts
1000V(CAT II) ±2.0% of rdg ±8 dgts
5.2. AC Voltage (Auto-ranging except 200mV)
Input Impedance: 10MΩ.
Frequency Range: 50 to 60Hz
Maximum Input: 600V DC/AC RMS. (CAT III)
Maximum Input: 1000V DC/AC RMS. (CAT II)
Range Resolution Accuracy
200.0uA 0.1uA ±1.0% of rdg ±3 dgts
2000uA 1uA
20.00mA 10uA ±1.5% of rdg ±3 dgts
200.0mA 100uA
10A 10mA ±2.5% of rdg ±5 dgts
5.3. DC Current (Auto-ranging for uA and mA)
Overload Protection: 0.2A / 250V and 10A / 250V Fuse.
Maximum Input: 200mA DC or 200mA AC RMS on uA /
mA ranges, 10A DC or AC RMS on 10A
range.