Range Resolution Accuracy
200.0uA 0.1uA ±1.5% of rdg ±5 dgts
2000uA 1uA
20.00mA 10uA ±1.8% of rdg ±5 dgts
200.0mA 100uA
10A 10mA ±3.0% of rdg ±7 dgts
5.4. AC Current (Auto-ranging for uA and mA)
Overload Protection: 0.2A / 250V and 10A / 250V Fuse.
Frequency Range: 50 to 60 Hz
Maximum Input: 200mA DC or 200mA AC RMS on uA /
mA ranges, 10A DC or AC RMS on 10A
range.
Range Resolution Accuracy
200A 0.1A ±1.0% of rdg ±3dgts
2000A 1A (meter only, Clamp-on
Adaptor accuracy not
included)
5.5. Clamp-on Adaptors DC Current
Sensor: Clamp-on Adaptor
(Note: not provided)
200A Range Input Sensitivity: 1mV/A
2000A Range Input Sensitivity: 1mV/A
Overload protection: 500V DC or AC RMS.
Range Resolution Accuracy
200A 0.1A ±1.5% of rdg ±3dgts
2000A 1A (meter only, Clamp-on
Adaptor accuracy not
included)
5.6. Clamp-on Adaptor AC Current
Sensor: Clamp-on Adaptor
(Note: not provided)
200A Range Input Sensitivity: 1mV/A
2000A Range Input Sensitivity: 1mV/A
Frequency Range: 50 to 60 Hz
Overload protection: 500V DC or AC RMS.