[3] Wiring in Handle for 4114S
Be sure to connect so that all slits
of the four Insulated receptacles
face the same direction as illustrated
below.
Insulated receptacle
(viewed from the wheel installation side)
Terminal of Switch
Terminal
Slit in Terminal
Insulator
Switch
Insulated receptacle
Connecting Insulated Receptacles
with Terminals of Switch
Fix the following lead wires
with this lead wire holder:
*2 Field lead wires (black)
*Lead wire of Soft start circuit (white)
*Lead wire of Soft start circuit (orange or red)
Rib
Pin
If Line filter is used,
guide two Field lead
wires (black) through it,
and put in this space.
Fix the following lead wires with this lead
wire holder, and put in this space:
*2 Field lead wires (purple, orange)
*2 Connecting lead wires (purple, orange)
from Brush holder
Put Soft start circuit
in this space.
Put Noise suppressor
in this space if used.
Switch
[Correct] [Wrong]
[2] Wiring in Handle for 4114
Switch
Fix the following lead wires
with this lead wire holder:
*2 Field lead wires (black)
*Lead wire of Soft start circuit (white)
*Lead wire of Soft start circuit (orange or red)
Do not put the lead wires
of Power supply cord on
this rib.
Avoid this pin to route
the lead wires of Power
supply cord.
Fix the following lead wires with this lead
wire holder, and put in this space:
*2 Field lead wires (purple, orange)
*2 Connecting lead wires (purple, orange)
from Brush holder
Put Noise suppressor
in this space if used.
Wiring diagram