EasyManuals Logo

Makita MAC2000 User Manual

Makita MAC2000
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
Tank pressure exceeds preset
pressure switch limit
Motor
overload protection
has
tripped
Fuse blown or arcuit breaker
tripped
Check valve stuck open
Pressure bleeder valve on
pressure switch has not unloaded
head pressure
Wrong wire gauge
in
cord
or
excessive extension
mrd
length
Loose electrical connections
Possible defective capacitor
Paint spray on internal motor
Parts
Possible defective motor
Motor
will
start
automatically when tank pressure drops below
kid-in pressure of pressure switch.
Let motor
cod
off,
and overload switch will automatically reset.
This
may
take several minutes.
0
Reprace
blown fuse or reset
circuit
breaker.
Do
not use
fuse
or circuit breaker with higher rating than that specified for your
branch circuit
0
Check for proper fuse; 'Fusetron'
type
T
is
acceptable.
0
Check for
low
voltage and
proper
extension
cord
size.
0
Disconnect
other
appliances
from circuit Operate compressor
on a
dedicated
circuit
Remove
and
dean
or
replace.
Bleed line by moving pressure switch lever
to
OFF position
before restarting.
If
bleeder valve does not open, replace
bleeder
vdw.
Chedc for
proper
gauge
and
extension cord length.
Contact
authorized service center.
~~
Have checked at service center.
Do
not operate the compressor
in the paint spray area.
Have checked at service center.
16
200-2 729

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Makita MAC2000 and is the answer not in the manual?

Makita MAC2000 Specifications

General IconGeneral
BrandMakita
ModelMAC2000
CategoryAir Compressor
LanguageEnglish

Related product manuals