Recycling the vacuum cleaner
As specified in European Directive 2012/19/EC on old electrical and electronic appliances,
used electrical goods must be collected separately and recycled ecologically. Contact your local
authorities or your nearest dealer for further information.
Guarantee
Our general conditions of business are applicable with regard to the guarantee. Subject to change as a
result of technical alterations.
Spare parts and accessories
Description Order no.
Filter element P-70219
Fleece filter bag 107418007
Disposal bag P-70297
Exploded drawings and parts lists are available on our homepage: www.makita.com
Troubleshooting
Fault Cause Remedy
‡ Motor does not start > Fuse in mains plug has blown. • Reset the fuse.
> Overload protection switch has
tripped.
• Switch off the vacuum cleaner
and allow it to cool for approx. 5
minutes. If it can not be started
again, contact the Makita
service department.
‡ Motor does not run in
automatic mode
> Power tool is defective or not
connected properly.
• Check that the power tool
works or that the plug is
inserted correctly.
‡ Reduced suction power > Suction power selected with
suction power control is to low.
• Set suction power in
accordance with section
“Suction power control”.
> Hose diameter does not
correspond with switch
position.
• Set correct switch position for
hose diameter.
> Clogged suction hose/nozzle. • Clean suction hose/nozzle.
> Seal/tank rim between the
upper section of the cleaner
and the dirt tank is dirty/
defective.
• Clean/replace seal.
> Filter bag is full. • See section “Replacing the
filter bag”.
> Filter element is clogged. • See section “Cleaning the filter
element” and “Replacing the
filter element”.
‡ No suction power during wet
cleaning
> Tank is full (floater closes the
suction opening).
• Switch off the cleaner. Empty
the tank.
‡ Voltage fluctuations > Impedance of power supply is
too high.
• Use a suitable extension cord
(see section “Technical data”).
• Connect the cleaner to another
socket closer to the fuse box.
Voltage fluctuations over 7
% should not occur if the
impedance at the transfer point
is ≤ 0.15 Ω.