2 – heating without time
limit
setting the maximum time
of power supply failure,
after which the controller
will return to the set
program execution
0 – inactive; resuming
operation is not time-limited
>0 – active; setting the time
from 1 h to 9 h; if the break
is longer, the controller will
not resume its operation
return to factory settings
(only after restaring the
controller)
0 – inactive
1 – active; return to factory
settings, though it is
required to turn the
controller power off and on
again
4.3.2. Programming for the washing segment.
The controller is protected against accidental entry into the service settings mode, assuming only
those available to the installer or service technician. These safeguards include:
− the necessity to press and hold the S button (enter settings) for approx. 15 sec.,
− the necessity to enter the access code (see section 4.3.1.),
− entering the access code in a few steps.
ATTENTION
Please do not share the access code with the direct users.
All changes in programming are made with the washing process switched off and at the same
time active washing segment (cooling is off).
4.3.2.1. Entering the settings.
The procedure for entering the access code to enter the settings and programming is shown
below.