EasyManua.ls Logo

MAKOT MCH-07 Series - User Manual

MAKOT MCH-07 Series
27 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Strona 1 z 27
PPH MAKOT
ul. Przewóz 34/304
30-716 Kraków, Poland
+48 537 872 522 [Sales]
dt@makot.pl [Support]
biuro@makot.pl [Sales]
1. DESCRIPTION.
The second generation of MCH-07 controller is a universal, combined controller intended for use
in milking machines (devices) and milk tanks. This controller allows you to cool the milk
contained in the tank and to carry out the milk tanks and milking devices washing process.
The controller is characterized by flexibility in adapting it to various requirements. It is fully
programmable at the installation stage, and at the same time protected against possible
interference by the user in the settings.
The controller consists of two complex segments:
cooling segment,
washing segment,
however, it is not possible, even accidentally, to activate the washing process during the cooling
process. The washing segment is activated only when the cooling is switched off.
The MCH-07 controller has a waterproof casing (protection class IP65), adapted for built-up.
On request there is also a version with a flange for panel mounting (variant MCH-07.f). Power as
well as control inputs and outputs are led through glands placed on the lower part of the casing.
However, on request, a version with glands placed on the back of the casing is provided, which
allows the controller to be installed in such a way that the wires are hidden (variant MCH-07.b).
In the set with the controller there is a temperature sensor. In version MCH-07T an additional
temperature sensor is connected, which controls the heating of the water temperature during
the washing process.
The temperature sensors are in the rubber cover (protection class IP68), ending with stainless
steel sleeve. The controller signals the failure of the temperature sensor.
power supply
230V AC 50/60 HZ
protection class
IP65
safety class
CE
Question and Answer IconNeed help?

Do you have a question about the MAKOT MCH-07 Series and is the answer not in the manual?

MAKOT MCH-07 Series Specifications

General IconGeneral
BrandMAKOT
ModelMCH-07 Series
CategoryController
LanguageEnglish

Summary

Controller Overview and Installation

Controller Overview and Features

General description of the MCH-07 controller, its segments, casing, and sensors.

Controller Technical Specifications

Lists power supply, protection class, and safety class for the MCH-07 controller.

Controller Installation and Connection

Step-by-step guide for physically installing and connecting the MCH-07 controller.

Cooling Segment Operation and Configuration

Cooling Segment Functionality

Explains how the cooling segment operates and its interaction with other functions.

Cooling Segment Technical Data

Provides detailed technical specifications for the cooling segment's operation.

Cooling Mode Controller Functions

Lists key functions of the controller during cooling operation.

Cooling Segment Programming

Instructions for programming and configuring the cooling segment.

Installer Operation of Cooling Segment

Details settings and operations accessible to installers for the cooling segment.

Cooling Segment Settings Table

Comprehensive table of adjustable parameters for the cooling segment.

Chiller Control Functionality

How the controller manages the chiller unit and its parameters.

Delaying Cooling Process Activation

Functionality to delay the start of the cooling process.

Automatic Stirrer Operation Modes

Configuration options for automatic stirrer operation.

Manual Stirrer Operation

How to manually control the stirrer's operation.

Temperature Value Saving in Cooling

How maximum and minimum temperatures are recorded during cooling.

Temperature Sensor Damage Monitoring

How the controller signals temperature sensor damage.

Returning Cooling Segment to Factory Settings

Procedure to reset the cooling segment to its default factory settings.

Direct User Cooling Settings

Cooling parameters configurable by the end-user.

Cooling Segment Operation Overview

General summary of how the cooling segment functions and its indicators.

Washing Segment Operation and Configuration

Washing Segment Functionality

Introduction to the washing segment and its activation.

Washing Segment Technical Data

Key technical specifications for the washing segment.

Washing Mode Controller Functions

Overview of the controller's capabilities within the washing mode.

Washing Program Management

Details on factory programs, creation, and modification of washing routines.

Returning Washing Segment to Factory Settings

Procedure to reset the washing segment to its default factory settings.

Pausing Washing Programs

How to temporarily halt and resume washing program execution.

Disabling Washing Programs

Method to completely stop and deactivate a washing program.

Water Heating Control (MCH-07 T)

Description of the water heating feature specific to the MCH-07T version.

Installer Use of Washing Segment

How installers configure and manage the washing segment.

Washing Segment Settings Table

Comprehensive table of adjustable parameters for the washing segment.

Washing Segment Programming Procedures

Guidelines for accessing and performing programming tasks.

Selecting Functions for Washing Program Editing

How to choose specific functions or programs to edit.

Editing Washing Programs

Detailed steps for modifying existing or creating new washing programs.

Washing System Test Mode

How to use test mode for accelerated verification of the washing system.

Factory Default Washing Programs

Description and tables of pre-programmed washing routines.

Direct User Washing Segment Operation

How end-users interact with the washing segment using minimal controls.

Starting Washing Program Operation

Steps to initiate the washing program and its indications.

Pausing and Resuming Washing Programs

How to temporarily halt and restart washing program execution.

Manual Pump and Stirrer Activation

Manual control options for the vacuum pump or stirrer.

Related product manuals