Loss of power supply interrupts the execution of the activated washing program. When the
correct supply voltage returns, the program will start in the same place where it was stopped.
In the settings of this function (UAP see section 4.3.1.), it is possible to set time limit for
returning to the interrupted program (in range from 1 h to 9 h).
4.2.4. Service / test mode.
This function allows moving successively to the next program steps without waiting for the
duration of the step to expire. The transition is made by pressing the appropriate button.
This function is only available to the installer.
4.2.5. Return to factory settings.
In the event of making a mistake while setting the controller's work or finding an incorrect
operation of the controller (at any stage of its use), it is possible to return to the factory settings
(Pd0d see section 4.3.1.).
4.2.6. Manual activation of the vacuum pump or the stirrer.
The controller is equipped with a button enabling manual activation of the vacuum pump or the
stirrer, regardless of the button , but depending from UPP parameter setting see section
4.3.1.
4.2.7. Program start function.
The program is started by manually pressing the button located on the front of the controller.
4.2.8. Pausing the program.
The controller allows to pause (hold) the program execution during its implementation. This
function allows to interrupt the program at any time and resume it, which happens exactly
in the same step, in which the program was paused.
4.2.9. Disabling the program.
The controller is equipped with a button that disables the program at any time, without
the possibility of resuming it at the switch-off point. Restarting the program will cause launching
the program from the very beginning.
4.2.10. Displaying the time remaining.
During the program execution, the controller displays the time remaining until the end of the
program.
ATTENTION
The time indicated on the display does not take into account the time of pouring water.