Strona 18 z 27
4.2.11. The function of dependence on the completion of pouring water from the hydrostatic
signal.
The controller allows to program the end of the water dispensing proces from obtaining a signal
from a hydrostatic. This function is secured by setting the maximum time for pouring water
in the event of mechanical suspension of the hydrostatic.
4.2.12. Water heating control (only MCH-07T version).
The MCH-07T version has a built-in temperature regulator that allows you to control the heating
of water. This function requires the connection of a temperature sensor and the setting of the
temperature of the water heating (the factory setting is 45
O
C).
4.3. Washing segment use by the installer.
The controller is factory-programmed for standard operating conditions for the purpose
of washing: milk cooler (2 programs) and milking devices (2 programs). Nevertheless, to ensure
proper operation of the controller under specific conditions, appropriate adjustments of the
operating parameters can be made, including the selection of the appropriate program. Deafault
washing programs can be edited according to the user's needs or you can create your own
program.
After the controller has been installed, the correct operation of the entire washing system can
also be checked in an accelerated mode using the test mode.
4.3.1. Table of settings for the washing segment.