limitation of the upper value for
the control temperature range
1
setting the temperature value from
-40
O
C to +99
O
C, every 1,0
O
C
setting the temperature from 1,0
O
C
to 20
O
C, every 0,1
O
C
blockade of control temperature
changes
0 – inactive; blockade is off
1 – active; blockade is on
delay of cooling start
for milking time
0 – inactive
>0 – active; setting the time from
0 min. to 99 min., every 1 min.
0 – inactive
>0 – active; setting the time from 0 h
to 18 h, every 1 h
minimum operting time
of the chiller (unit)
0 – inactive
>0 – active; setting the time from
0 min. to 60 min., every 1 min.
maximum operating time
of the chiller (unit)
2
0 – inactive
>0 – active; setting the time from 0 h
to 9 h, every 1 h
minimum standstill time
of the chiller (unit)
0 – inactive
>0 – active; setting the time from
0 min. to 60 min., every 1 min.
changing the parameter value is not
recommended
3
0 – work according to the times set in
E1 and E2, independent of the
operation of the chiller (unit)
1 – continuous work during
the chiller (unit) operation,
and during the standstill of the chiller
(unit), the stirrer works according
to times set in E1 and E2
standstill time of the stirrer
setting the time from 1 min. to
60 min., every 1 min.
operation time of the stirrer
setting the time from 1 min. to
60 min., every 1 min.
0 – continuous work
>0 – setting the time from 1 min. to
60 min., every 1 min.
changing the parameter value is not
recommended
3
delay in measuring the maximum
and minimum temperatures after
turning on the cooling process
setting the time from 0 h to 18 h,
every 1 h
return to factory settings
scaling the temperature sensor
4
setting the temperautre from
-10,0
O
C to +10,0
O
C, every 0,1
O
C