2. TECHNICAL DATA.
temperature measuring range
from -40
O
C to +120
O
C
control temperature range
from -40
O
C to +120
O
C
(decreased by a set hysteresis)
measuring resolution of the temperature
measurer (resolution of control
temperature settings)
1
O
C for the range below -9.9
O
C and over
+100
O
C
0.2
O
C for the range from -10
O
C to +100
O
C
control hysteresis
[programmable parameter]
from 0.2
O
C to 10
O
C for the range from
-10
O
C to +100
O
C
from 1
O
C to 10
O
C for the range <-10
O
C and
>+100
O
C
operation time of the stirrer / ventilator
[programmable parameter]
from 1 min. to 60 min.
standstill time of the stirrer / ventilator
[programmable parameter]
from 1 min. to 60 min.
temporary operation time of the stirrer /
ventilator
[programmable parameter]
from 1 min. to 60 min.
time delay for switching the chiller (unit)
/ stirrer on after the regulator is turned
on or the power supply decay occurs
from 1 sec. to 999 sec.
length of control sensors
5 m
type of temperature sensor
thermistor NTC
type of temperature measurer
digital LED
load capacity of relay contacts controlling
the chiller (unit) / heating system
30 A 250 V AC
load capacity of relay contacts controlling
the stirrer / ventilator
10 A 250 V AC
power supply
230 V AC 50 HZ
protection class
IP 65
safety class
CE