Commissioning and operation
34
>exit< Back get-mmds-time
You return to the main menu by pressing the PRG key
Prg
or the Menu key
ALARMS
Men
. In
the event of an input error, you can use the function “back” to repeat the input.
An additional function makes it possible to download the system time of the MMDS cen-
tral unit into the display module. To do so, the selection cursor is placed on “get-mmds-
time” and confirmed with PRG
Prg
. If the central unit is active (engine ignition on), the
date and time are overwritten and the following message appears briefly in the display.
>>> LOAD MMDS-SYSTEM-TIME <<<
If the central unit is switched off (engine ignition off), nothing is changed and the following
message appears:
>>> NO MMDS-TIME RECEIVED <<<
The selection cursor then jumps back to the second last line to the item “exit”:
Ship-specific alarms
There is the possibility to connect 11 ship-specific alarms or warnings and to generate
these using software. The text of the alarms or warnings is entered by the shipyard.
In the event of an alarm, the corresponding measurement point text appears on the
alarm page; the program switches automatically into the alarm menu. In the case of
warnings, the program does not switch automatically into the alarm menu.