EasyManuals Logo

Man V28/32H User Manual

Man V28/32H
392 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #222 background imageLoading...
Page #222 background image
Properties Limit Unit
1)
Dust (sand, cement, CaO, Al
2
O
3
etc.) max. 5 mg/Nm
3
Chlorine max. 1.5
Sulphur dioxide (SO
2
) max. 1.25
Hydrogen sulphide (H
2
S) max. 5
Salt (NaCl) max. 1
1)
One Nm
3
corresponds to one cubic meter of gas at 0 °C and 101.32 kPa.
Table 1: Typical values for intake air (combustion air) that must be complied with
Explosion caused by flammable intake air
Explosion caused by flammable intake air can result in severe injuries
and damage.
Intake air must not contain any flammable gases.
Intake air is not explosive.
Intake air is not drawn in from the ATEX Zone.
Quality guidelines (conventional and Common Rail
engines)
Quality guidelines (conventional and Common Rail engines)
General
2017-01-10 - de
010.000.023-17
MAN Diesel & Turbo
2 (2) D010.000.023-17-0001 EN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Man V28/32H and is the answer not in the manual?

Man V28/32H Specifications

General IconGeneral
BrandMan
ModelV28/32H
CategoryPortable Generator
LanguageEnglish

Related product manuals