3-18
C - EVERY 250 HOURS OF OPERATION
C1 - FRONT & REAR AXLE DIFFERENTIAL OIL LEVEL
CHECK
Set the lifting platform on a horizontal surface, with the engine switched off.
DIFFERENTIAL:
- Remove the plug 1 (Fig. C1/1); the oil level should be flush with the hole.
- If necessary, top up the oil through the same hole (see the LUBRICANTS section).
- Refit the plug 1 and tighten it (Fig. C1/1) (tightening torque: 6 daNm)
AXLES:
- Remove the level plug 2 (Fig. C1/2: front axle) (Fig. C1/3: rear axle); the oil level
should be flush with the hole.
- If necessary, top up the oil through the same hole (see the LUBRICANTS section).
- Refit the level plug 2 and tighten it (Fig. C1/2: front axle) (Fig. C1/3: rear axle)
(tightening torque: 6 daNm)
C2 - MACHINE STICKERS
CHECK
- Check that the safety stickers are present (see: 1 – SAFETY STICKERS).
C1/1
C1/2
C1/3
1
2
2
547408 EN (15/05/2012)