2-49
3 - FINTRONIC ANTI-START SYSTEM
OPERATION
- Switch on the lift truck and set the black key A next to the antenna B (maximum
80 mm).
- Wait a few seconds for red LED C to go out before starting the lift truck.
NOTE: You can restart the lift truck within 20 seconds of stopping it: after this time, the
anti-start system reacts and red LED C flashes.
4 - MODCLE ANTI-START SYSTEM
OPERATION
- Switch on lift truck ignition, red led 1 will flash.
- Apply key 2 to its base 3, and withdraw the moment the system emits a continuous beep,
and led 1 turns green.
- Start the lift truck within the next 20 seconds; otherwise the anti-theft system will
be reactivated and red led 1 will flash.
NOTE: You can restart the lift truck within 20 seconds of stopping it: after this time, the
anti-start system reacts and red LED C flashes.
5 - ELECTRICAL PROVISION ON JIB
Enables an electrical function to be used at the head of the jib.
OPERATION
- Set switch 1 to position A to enable the electrical provision. The indicator light will come
on when it is enabled.
6 - QUICK-RELEASE COUPLER ON ATTACHMENT CIRCUIT
7 - ANGULAR SECTOR ON JIB
The angular sector displays the jib angle, and thus
improves the reading of the load charts.
MT 1440 E3 MT 1840 E3