OPERATING CONTROLS AND PROCEDURES OPERATOR MANUAL 600E2
3-18 PUBLISHED 04-26-2019 CONTROL # 113-09
Will two radio remote units in the same vicinity
operate each other?
No. Each receiver and transmitter have address codes which are set
by the factory and are shipped as a set. Therefore, serial numbers
should be recorded for future reference should assistance from the
factory be necessary.
Is the unit protected from environmental condi-
tions?
Yes. The unit is operable in temperature ranges from -25°F to +150°F
(-32°C to +66°C). Placement of the receiver is recommended to be in
the cab or tool box. The printed circuit boards in both the receiver and
transmitter are coated with conformal material for protection against
high humidity and moisture. The transmitter may be used in rainy con-
ditions, do mot submerge the unit in water for any prolonged period of
time. Should water get inside, remove top cover of transmitter and
allow components to air dry. Replace battery, reassemble and continue
use.
What type of battery is used? A standard alkaline 9 volt battery is recommended. The Duracell Cop-
per Top is a representative battery that fits the battery enclosure cor-
rectly and provides an acceptable service life.
How long will the battery last? This will depend on the frequency and duration of use. Customers who
use their wireless controller extensively have indicated a span of 4 to
10 weeks.
How many operations can be done simultane-
ously?
Two functions can be activated at the same time. However, a single
flow control is used to supply both functions. The single flow control
allows the function operating at the lower pressure to take priority. In
some cases, the function demanding the higher pressure will remain
stationary until the lower pressure function reaches the end of stroke or
is deactivated.
Question Answer
Fo
r
Reference
Only

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc National Crane 600E-2 and is the answer not in the manual?

Manitowoc National Crane 600E-2 Specifications

General IconGeneral
BrandManitowoc
ModelNational Crane 600E-2
CategoryConstruction Equipment
LanguageEnglish

Related product manuals