Section 4 Maintenance
Part Number 00000xxxx 05/10 11
B. Remove the Vinyl Hose
Disconnect the water pump discharge hose from the
distribution tube and water pump.
C. Remove the Water Pump
Disconnect the water pump power cord.
Loosen the screws that hold the water pump in place.
Lift the water pump and bracket assembly up and off
the screws.
Removing the Water Pump
D. Remove the Water Trough
Remove the screws holding the water trough to the
walls of the cabinet.
Step 7 Mix a solution of cleaner and warm water.
Depending on the amount of mineral buildup, a larger
quantity of solution may be required. Use the ratio in the
table below to mix enough solution to thoroughly clean
all parts.
Step 8 Use half of the cleaner/water solution to clean
all components. The cleaner solution will foam when it
contacts lime scale and mineral deposits; once the
foaming stops use a soft bristle brush, sponge or cloth
(not a wire brush) to carefully clean the parts. Soak the
parts for 5 minutes (15 – 20 minutes for heavily scaled
parts). Rinse all components with clean water.
Step 9 While components are soaking, use half of the
cleaner/water solution to clean all foodzone surfaces of
the ice machine and bin. Use a nylon brush or cloth to
thoroughly clean the following ice machine areas:
Evaporator plastic parts – including top, bottom and
sides
Bin bottom, sides and top
Rinse all areas thoroughly with clean water.
Step 10 Mix a solution of sanitizer and warm water.
Step 11 Use half of the sanitizer/water solution to
sanitize all removed components. Use a cloth or sponge
to liberally apply the solution to all surfaces of the
removed parts or soak the removed parts in the
sanitizer/water solution. Do not rinse parts after
sanitizing.
Step 12 Use half of the sanitizer/water solution to
sanitize all foodzone surfaces of the ice machine and
bin. Use a cloth or sponge to liberally apply the solution.
When sanitizing, pay particular attention to the following
areas:
Evaporator plastic parts - including top, bottom and
sides
Bin bottom, sides and top
Do not rinse the sanitized areas.
Step 13 Replace all removed components.
Step 14 Reapply power and water to the ice machine
and place the toggle switch in the WASH position.
Solution Type Water Mixed with
Cleaner 4L. (1 gal)
500 ml (16 oz)
cleaner
Solution Type Water Mixed With
Sanitizer 23 L. (6 gal )
120 ml
(4 ounces) sanitizer

Other manuals for Manitowoc QM30 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QM30 Series and is the answer not in the manual?

Manitowoc QM30 Series Specifications

General IconGeneral
BrandManitowoc
ModelQM30 Series
CategoryIce Maker
LanguageEnglish

Related product manuals