Section 3 Ice Machine Operation
3-5
ICE THICKNESS CHECK
The ice thickness probe is factory-set to maintain
the ice bridge thickness at 1/8” (3.2 mm).
1. Inspect the bridge connecting the cubes. It
should be about 1/8” (3.2 mm) thick.
2. If adjustment is necessary, turn the ice thickness
probe adjustment screw clockwise to increase
bridge thickness, or counterclockwise to
decrease bridge thickness.
NOTE: Turning the adjustment 1/3 of a turn will
change the ice thickness about 1/16” (1.5 mm).
Ice Thickness Check
Make sure the ice thickness probe wire and the
bracket do not restrict movement of the probe.
SV1208
1/8” (3.2MM)
ICE BRIDGE
THICKNESS
ADJUSTING
SCREW