66 Part Number: 000015431 Rev01 5/19
Single & Twin Evaporator QuietQube® Models
Energized Parts Chart
Ice Making
Sequence of
Operation
Water
Pump
Harvest
Valve(s)
Air
Pumps
Water Inlet
Valve
Water
Dump
Valve
Liquid Line
Solenoid
Valve
Contactor
Refrigeration
Compressor &
Condenser Fan
Motor*
Length of
Time
Freeze Sequence
Off Off Off
May cycle
On/Off
Off On On
Initial Start-Up is
120 Seconds
30 Seconds thereafter
3. Pre chill
4. Freeze
On Off Off
Cycles Off
then On/Off,
two more
times
Off On On
Until Ice contact with
ice thickness probe
Harvest Sequence
On On On Off On On On
Factory-set at
45 Seconds
5. Water Purge