Part Number 000007661 11/16 37
Step 8 Disconnect power, then drain the water from
the evaporator and reservoir through the evaporator/
reservoir drain line - Using a pitcher, fill and drain the
evaporator/reservoir 4 times and reinsert the hose into
the hose clip.
Step 9 Refer to chart and premix water and sanitizer.
Amount of Luke Warm
Water
Amount of Sanitizer
1 Gallon (4 L) Water 1/2 ounce (15 ml)
Step 10 Fill reservoir and evaporator with sanitizer/
water solution.
Step 11 Step 11 Verify the compressor rocker switch is
in the OFF position, then reconnect power and run the
gearmotor for 10 minutes.
• During the 10 minute period rinse cleaner from
compression nozzle with potable water and then
soak in sanitizer/water solution.
Step 12 Move the compressor rocker switch to the ON
position. The ice machine will make ice with the sanitizer/
water solution and deposit the ice in the bin/ dispenser.
Make ice for 5 minutes - add sanitizer/water solution as
the water level in the reservoir drops.
NOTE: Do not allow the sanitizer/water level to drop
below the sensing probes. The ice machine will start a 20
minute delay period if the sensing probes lose contact
with the water for more than 10 seconds.
Step 13 Move the compressor rocker switch to the OFF
position and disconnect power.
Step 14 Drain the evaporator/reservoir and reinsert the
drain hose into the hose clip.
Step 15 Reinstall the ice compression nozzle and
reservoir cover. Verify the ice tube is in place and does not
contact the condenser fan blade.