Head Section Electrical
** All conductors must be solid copper wire
* Not available on S2070C models.
15 amp
15 amp
15 amp
#14 Solid Copper
Conductor
1.1
0.6
0.6
15 amp
15 amp
15 amp
115/1/60
208-230/1/60
230/1/50*
S1470C
S1870C
S2070C
15 amp
15 amp
#14 Solid Copper
Conductor
2.5
1.5
15 amp
15 amp
115/1/60
230/1/50
S1200C
15 amp
15 amp
#14 Solid Copper
Conductor
2.5
1.5
15 amp
15 amp
115/1/60
230/1/50
S1000C
15 amp
15 amp
#14 Solid Copper
Conductor
1.4
0.8
15 amp
15 amp
115/1/60
230/1/50
IB0620C
IB0820C
IB1020C
15 amp
15 amp
#14 Solid Copper
Conductor
1.1
1.5
15 amp
15 amp
115/1/60
230/1/50
S0850C
15 amp
15 amp
#14 Solid Copper
Conductor
1.1
0.6
15 amp
15 amp
115/1/60
230/1/50
S0600C
Minimum
Breaker Size
Required by
Manitowoc
**Minimum Wire
Size Required by
Manitowoc
Total
Amps
Maximum
Fuse/Circuit
Breaker
Voltage Phase Cycle Ice Machine
Due to continuous improvements, this information is for reference only. Please refer
to the ice machine and/or condensing unit serial number tags to verify electrical
data. Serial tag information overrides information listed here.