Suction Temperature High Checklist
Improper Installation
Refer to “Installation/Visual Inspection Checklist” on
page 164
Discharge Pressure
Discharge temperature is too high, and is affecting
suction temperature, refer to “Discharge Line
Temperature High Checklist” on page 171.
Improper Refrigerant Charge
Overcharged
Wrong type of refrigerant
Non-condensible in system
Other
Non-Manitowoc components in system
Harvest valve leaking
TXV flooding (check bulb mounting)
Defective compressor