Do you have a question about the Marantz PM-KI-PEARL-LITE and is the answer not in the manual?
Mandatory safety test procedure after servicing to prevent electrical hazards.
Procedure to check for electrical leakage before returning the unit to the customer.
Identification and importance of safety-critical parts in the unit.
Detection of abnormalities in the Power Amplifier section by PROT-1 signal.
Detection of abnormalities in the power supply circuit by PROT-2 signal.
Diagnosing issues when the unit does not power on and the standby LED is off.
Diagnosing issues when the unit does not power on and the standby LED flashes.
Mandatory safety test procedure after servicing to prevent electrical hazards.
Procedure to check for electrical leakage before returning the unit to the customer.
Identification and importance of safety-critical parts in the unit.
Detection of abnormalities in the Power Amplifier section by PROT-1 signal.
Detection of abnormalities in the power supply circuit by PROT-2 signal.
Diagnosing issues when the unit does not power on and the standby LED is off.
Diagnosing issues when the unit does not power on and the standby LED flashes.
| Damping factor | 100 |
|---|---|
| Amplifier class | - |
| Frequency range | 5 - 100000 Hz |
| Input sensitivity | 2 mV |
| Audio output channels | 2.0 channels |
| Peak power per channel | 100 W |
| Signal-to-Noise Ratio (SNR) | 106 dB |
| Total Harmonic Distortion (THD) | 0.0002 % |
| RMS power output per channel (8 Ohm) | 70 W |
| Pre out port | Yes |
| Audio (L/R) in | 6 |
| Audio (L/R) out | 2 |
| Headphone outputs | 1 |
| Speakers connectivity type | RCA |
| Purpose | Home |
| Product color | Gold, Silver |
| Volume control | Rotary |
| Cables included | AC |
| Connectivity technology | Wired |
| Built-in display | No |
| Power consumption (standby) | 0.3 W |
| Power consumption (typical) | 200 W |
| Depth | 379 mm |
|---|---|
| Width | 440 mm |
| Height | 129 mm |
| Weight | 12000 g |