7 Adjustments and servicing procedures
7.1 Air filter
Changing the air filter
Air filter
Procedure:
Step Action
1 Stop the compressor, close the air outlet valve and switch off the voltage.
2 Remove the front panel and the top panel of the compressor housing.
3 Unscrew the filter cover (AF) and remove the filter element. Discard the air filter
element.
4 Fit the new element and screw on the filter cover.
5 Refit the top and front panels.