WHEN USING ELECTRIC APPLIANCES, BASIC
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO
REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, AND
INJURY TO PERSONS, INCLUDING THE FOLLOWING:
1. Read all instructions before installing or using this heater.
2. This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes, etc. and
curtains at least 3 feet (0.9 m) from the front of the heater.
3. Extreme caution is necessary when any heater is used by or
near children or invalids and whenever the heater is left
operating and unattended.
4. Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a
reputable electrician before using.
5. Do not use outdoors.
6. To disconnect heater, turn controls to OFF, and turn off
power to heater circuit at main disconnect panel.
7. Do not insert or allow foreign objects to enter any ventilation
or exhaust opening as this may cause an electric shock, fire,
or damage to the heater.
8. To prevent a possible fire, do not block air intake or exhaust
in any manner.
9. A heater has hot and arcing or sparking parts inside. Do not
use it in areas where gasoline, paint, or flammable liquids
are used or stored.
10. Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.
11. This heater is intended for comfort heating applications and
not intended for use in special environments. Do not use in
damp or wet locations such as marine or greenhouse or in
areas where corrosive or chemical agents are present.
12. When installing, see INSTALLATION INSTRUCTIONS for
additional warnings and precautions.
13. For safe and efficient operation, and to extend the life of your
heater, keep your heater clean - See MAINTENANCE
INSTRUCTIONS.
SAVE THESE INSTRUCTIONS
!
Installation, Operation & Maintenance Instructions
WARNING
IMPORTANT INSTRUCTIONS
PPD 41511 7/14 5200-11210-000 (ISS 1.0)
3
64 mm
99 mm
39 mm
35 mm
4
86
mm
400 mm
464
mm
14-5/16”
1
-3/8”
1-1/2”
3-7/8”
18-1/4”
19-1/8”
15-3/4”
K Series
Fan Forced
Wall Heaters
Specifications
M
ODEL SHIP WT.
NUMBER VOLTAGE WATTAGE PHASE CFM AMPS (LBS.)
K
151FC 120 1500 1 100 12.5 22
K204FC 240/208 2000/1500 1 100 8.3/7.3 22
K303FC 347 3000 1 100 8.6 25
K304FC 240 3000 1 100 12.5 22
K
306FC 600 3000 3 100 5.0 25
K404FC 240/208 4000/3000 1 100 16.7/14.4 22
K403FC 347 4000 1 100 11.5 25
K406FC 600 4000 3 100 6.7 25
K408FC 208V 4000 1 100 19.2 22
K483FC 347 4800 1 100 13.8 25
K484FC 240/208 4800/3600 1 100 20.9/17.3 22
K486FC 600 4800 3 100 8 25
K4083FC 208V 4000 3 100 11.1 23
K487FC 277V/240 4800/3600 1 100 17.3 23
K488FC 208V 4800 1 100 23.1 23
K4883FC 208V 4800 3 100 13.3 23